Citation: | Please cite this article as: ZHAI GY, FENG XX, WANG JL, LIU YY, GUO QY, ZHOU YJ. Optical coherence tomography-guided excimer laser coronary angioplasty in overlapping stents with severe under-expansion and underlying calcification. J Geriatr Cardiol 2021; 18(2): 146−149. DOI: 10.11909/j.issn.1671-5411.2021.02.006 |
[1] |
Lam SC, Bertog S, Sievert H. Excimer laser in management of underexpansion of a newly deployed coronary stent. Catheter Cardiovasc Interv 2014; 83: E64−E68. doi: 10.1002/ccd.25030
|
[2] |
Tai Z. Excimer laser in contrast for the treatment of acute MI caused by thrombosis of underexpanded stent. Clin Case Rep 2018; 6: 1457−1463. doi: 10.1002/ccr3.1537
|
[3] |
Egred M, Brilakis ES. Excimer laser coronary angioplasty (ELCA): fundamentals, mechanism of action, and clinical applications. J Invasive Cardiol 2020; 32: E27−E35.
|
[4] |
Ashikaga T, Yoshikawa S, Isobe M. The effectiveness of excimer laser coronary atherectomy with contrast medium for underexpanded stent: the findings of optical frequency domain imaging. Catheter Cardiovasc Interv 2015; 86: 946−949. doi: 10.1002/ccd.25915
|
[5] |
Latib A, Takagi K, Chizzola G, et al. Excimer laser lesion modification to expand non-dilatable stents: the ELLEMENT registry. Cardiovasc Revasc Med 2014; 15: 8−12. doi: 10.1016/j.carrev.2013.10.005
|
[6] |
Rawlins J, Din JN, Talwar S, et al. Coronary intervention with the excimer laser: review of the technology and outcome data. Interv Cardiol 2016; 11: 27−32. doi: 10.15420/icr.2016:2:2
|
[7] |
Veerasamy M, Gamal AS, Jabbar A, et al. Excimer laser with and without contrast for the management of under-expanded stents. J Invasive Cardiol 2017; 29: 364−369.
|
[8] |
Egred M. A novel approach for under-expanded stent: excimer laser in contrast medium. J Invasive Cardiol 2012; 24: E161−E163.
|
[9] |
Andreou AY, Kyriakou T, Mavroudis C. Excimer laser-facilitated stent expansion: the effect of contrast enhancement. Hellenic J Cardiol 2017; 58: 303−305. doi: 10.1016/j.hjc.2017.02.004
|
[10] |
Lee T, Shlofmitz RA, Song L, et al. The effectiveness of excimer laser angioplasty to treat coronary in-stent restenosis with peri-stent calcium as assessed by optical coherence tomography. EuroIntervention 2019; 15: e279−e288. doi: 10.4244/EIJ-D-18-00139
|
[11] |
Nan J, Joseph TA, Bell MR, et al. Outcomes of excimer laser-contrast angioplasty for stent under-expansion. EuroIntervention 2020; 23: EIJ-D-19-01074. doi: 10.4244/EIJ-D-19-01074
|
[12] |
Tcheng JE, Wells LD, Phillips HR, et al. Development of a new technique for reducing pressure pulse generation during 308-nm excimer laser coronary angioplasty. Cathet Cardiovasc Diagn 1995; 34: 15−22. doi: 10.1002/ccd.1810340306
|
[13] |
Nakabayashi K, Hata S, Kaneko N, et al. Excimer laser coronary angioplasty with the non-flushing technique for frequent in-stent sestenosis due to double-layered and long-standing stent under-expansion. Cardiovasc Revasc Med 2020; 21: 1619−1620. doi: 10.1016/j.carrev.2020.03.019
|
[14] |
Yin D, Maehara A, Mezzafonte S, et al. Excimer laser angioplasty-facilitated fracturing of napkin-ring peri-stent calcium in a chronically underexpanded stent: documentation by optical coherence tomography. JACC Cardiovasc Interv 2015; 8: e137−e139. doi: 10.1016/j.jcin.2015.02.018
|